Ecotec F70
BOILER: Ecotec F70
Information:
When replacing both components, after being turned on, the appliance goes to fault and displays the error message “F70”.
• In the second diagnostic level, under the diagnostic number “d.93” enter the number of appliance variant according to Table 9.1 (see section 8.1.2).
The electronics is now set to the appliance type and the parameters of all adjustable diagnostics numbers correspond to the factory settings.
Disclaimer: Whilst every attempt is made to ensure the accuracy of information contained on this help centre, errors can occasionally occur. The Vaillant Group cannot accept any responsibility for any reliance upon such information, any omissions or any subsequent loss or damage.Vaillant Group recommends that only qualified, gas safe registered engineers carry out repairs, installation or servicing.Vaillant Group reserves the right to amend , update, or withdraw any information within the help centre without prior notice.
All Images and content in this help centre is a copyright of Vaillant and must not be reproduced without the express permission of Vaillant Group. Such permission may be obtained by emailing servicevisit@vaillant.com with details of proposed usage.